TY  - JOUR
AU  - Abramowicz, H.
AU  - Abusleme, A.
AU  - Afanaciev, K.
AU  - Aguilar, J.
AU  - Alvarez, E.
AU  - Avila, D.
AU  - Benhammou, Y.
AU  - Bortko, L.
AU  - Borysov, O.
AU  - Bergholz, M.
AU  - Bozovic-Jelisavcic, I.
AU  - Castro, E.
AU  - Chelkov, G.
AU  - Coca, C.
AU  - Daniluk, W.
AU  - Dumitru, L.
AU  - Elsener, K.
AU  - Fadeyev, V.
AU  - Firlej, M.
AU  - Firu, E.
AU  - Fiutowski, T.
AU  - Ghenescu, V.
AU  - Gostkin, M.
AU  - Henschel, H.
AU  - Idzik, M.
AU  - Ishikawa, A.
AU  - Kananov, S.
AU  - Kollowa, S.
AU  - Kotov, S.
AU  - Kotula, J.
AU  - Kozhevnikov, D.
AU  - Kruchonok, V.
AU  - Krupa, B.
AU  - Kulis, Sz.
AU  - Lange, W.
AU  - Lesiak, T.
AU  - Levy, A.
AU  - Levy, I.
AU  - Lohmann, W.
AU  - Lukic, S.
AU  - Milke, C.
AU  - Moron, J.
AU  - Moszczynski, A.
AU  - Neagu, A. T.
AU  - Novgorodova, O.
AU  - Oliwa, K.
AU  - Orlandea, M.
AU  - Pandurovic, M.
AU  - Pawlik, B.
AU  - Preda, T.
AU  - Przyborowski, D.
AU  - Rosenblat, O.
AU  - Sailer, A.
AU  - Sato, Y.
AU  - Schumm, B.
AU  - Schuwalow, S.
AU  - Smiljanic, I.
AU  - Smolyanskiy, P.
AU  - Swientek, K.
AU  - Teodorescu, E.
AU  - Terlecki, P.
AU  - Wierba, W.
AU  - Wojton, T.
AU  - Yamaguchi, S.
AU  - Yamamoto, H.
AU  - Zawiejski, L.
AU  - Zgura, I. S.
AU  - Zhemchugov, A.
TI  - Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
JO  - Journal of Instrumentation
VL  - 05
IS  - arXiv:1411.4431
SN  - 1748-0221
CY  - London
PB  - Inst. of Physics
M1  - PUBDB-2015-00514
M1  - arXiv:1411.4431
SP  - P05009
PY  - 2015
N1  - OA
AB  - Detector-plane prototypes of the very forward calorimetry of a future detector at an e<sup>+</sup>e<sup>−</sup> collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio for different feedback schemes and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
KW  - electron positron: linear collider (INSPIRE)
KW  - electron: beam (INSPIRE)
KW  - numerical calculations: Monte Carlo (INSPIRE)
KW  - showers: spatial distribution (INSPIRE)
KW  - calorimeter (INSPIRE)
KW  - performance (INSPIRE)
KW  - electronics: readout (INSPIRE)
KW  - semiconductor detector (INSPIRE)
KW  - noise (INSPIRE)
KW  - data analysis method (INSPIRE)
LB  - PUB:(DE-HGF)16 ; PUB:(DE-HGF)15
DO  - DOI:10.1088/1748-0221/10/05/P05009
UR  - https://bib-pubdb1.desy.de/record/205981
ER  -