TY  - CONF
AU  - Vagin, Pavel
AU  - Neumann, Paul
AU  - Tischer, Markus
TI  - Magnetic Measurement Developments for Undulators
CY  - Geneva
PB  - JACoW, Geneva, Switzerland
M1  - PUBDB-2015-00047
SN  - 978-3-95450-132-8
SP  - 2016-2018
PY  - 2014
AB  - FLASH2 is an extension of the present VUV-FEL facility at DESY. It includes a separate tunnel with a 12 x 2.5m = 30m long planar hybrid undulator. The undulators have 31.4mm period length and 1T field at a minimum gap of 9mm. The paper presents recent progress in the magnetic measurements of these undulators. Several specific details of the measurement tools will be discussed like peculiarities in the Hall probe calibration and noise, positioning accuracy and synchronization of voltage measurement with probes movement during scan, noise issues of various voltage integrators for stretched wire and search coil measurements.
T2  - International Particle Accelerator Conference IPAC
CY  - 15 Jun 2014 - 20 Jun 2014, Dresden (Germany)
Y2  - 15 Jun 2014 - 20 Jun 2014
M2  - Dresden, Germany
KW  - Accelerator Physics (Other)
KW  - 02 Synchrotron Light Sources and FELs (Other)
KW  - T15 Undulators and Wigglers (Other)
LB  - PUB:(DE-HGF)8 ; PUB:(DE-HGF)7
DO  - DOI:10.18429/JACoW-IPAC2014-WEPRO034
UR  - https://bib-pubdb1.desy.de/record/205483