% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.

@ARTICLE{Adamczyk:154770,
      author       = {Adamczyk, L. and Andruszkow, J. and Bold, T. and Borzemski,
                      P. and Buettner, C. and Caldwell, A. and Chwastowski, J. and
                      Daniluk, W. and Drugakov, V. and Eskreys, A. and Figiel, J.
                      and Galas, A. and Gil, M. and Helbich, M. and Januschek, F.
                      and Jurkiewicz, P. and Kisielewska, D. and Klein, U. and
                      Kotarba, A. and Lohmann, W. and Ning, Y. and Oliwa, K. and
                      Olkiewicz, K. and Paganis, S. and Pieron, J. and Przybycien,
                      M. and Ren, Z. and Ruchlewicz, W. and Schmidke, W. and
                      Schneekloth, U. and Sciulli, F. and Stopa, P. and
                      Sztuk-Dambietz, J. and Suszycki, L. and Sutiak, J. and
                      Wierba, W. and Zawiejski, L.},
      title        = {{M}easurement of the {L}uminosity in the {ZEUS}
                      {E}xperiment at {HERA} {II}},
      reportid     = {DESY-2013-01083, DESY-2013-081. arXiv:1306.1391},
      year         = {2013},
      note         = {25 pages, 11 figures},
      abstract     = {The luminosity in the ZEUS detector was measured using
                      photons from electron bremsstrahlung. In 2001 the HERA
                      collider was upgraded for operation at higher luminosity. At
                      the same time the luminosity-measuring system of the ZEUS
                      experiment was modified to tackle the expected higher photon
                      rate and synchrotron radiation. The existing
                      lead-scintillator calorimeter was equipped with radiation
                      hard scintillator tiles and shielded against synchrotron
                      radiation. In addition, a magnetic spectrometer was
                      installed to measure the luminosity independently using
                      photons converted in the beam-pipe exit window. The
                      redundancy provided a reliable and robust luminosity
                      determination with a systematic uncertainty of $1.7\%.$ The
                      experimental setup, the techniques used for luminosity
                      determination and the estimate of the systematic uncertainty
                      are reported.},
      cin          = {ZEUS},
      ddc          = {530},
      cid          = {I:(DE-H253)ZEUS-20120806},
      pnm          = {Experiments at HERA (ZEUS) (POF2-511)},
      pid          = {G:(DE-H253)POF2-HERA-Exp.-(ZEUS)-20130405},
      experiment   = {EXP:(DE-588)4276505-5},
      typ          = {PUB:(DE-HGF)25 / PUB:(DE-HGF)15},
      eprint       = {1306.1391},
      howpublished = {arXiv:1306.1391},
      archivePrefix = {arXiv},
      SLACcitation = {$\%\%CITATION$ = $arXiv:1306.1391;\%\%$},
      url          = {https://bib-pubdb1.desy.de/record/154770},
}