% IMPORTANT: The following is UTF-8 encoded.  This means that in the presence
% of non-ASCII characters, it will not work with BibTeX 0.99 or older.
% Instead, you should use an up-to-date BibTeX implementation like “bibtex8” or
% “biber”.
@INPROCEEDINGS{Krieger:315522,
      author       = {Krieger, Christoph and Desch, Klaus and Kaminski, Jochen
                      and Lupberger, Michael and Vafeiadis, Theodoros},
      title        = {{A}n {I}n{G}rid based {L}ow {E}nergy {X}-ray {D}etector},
      address      = {Hamburg},
      publisher    = {Verlag Deutsches Elektronen-Synchrotron},
      reportid     = {PUBDB-2016-05929},
      isbn         = {978-3-935702-59-1},
      series       = {DESY-PROC},
      pages        = {147-150},
      year         = {2014},
      comment      = {Krieger, Christoph "An InGrid based Low Energy X-ray
                      Detector" in Proceedings, 10th Patras Workshop on Axions,
                      WIMPs and WISPs (AXION-WIMP 2014) / Tsesmelis, Emmanuel,
                      Maroudas, Marios (eds.), Verlag Deutsches
                      Elektronen-Synchrotron : 2014 ; AXION-WIMP 2014 : 10th
                      Patras Workshop on Axions, WIMPs and WISPs, 2014-06-29 -
                      2014-07-04, Geneva},
      booktitle     = {Krieger, Christoph "An InGrid based
                       Low Energy X-ray Detector" in
                       Proceedings, 10th Patras Workshop on
                       Axions, WIMPs and WISPs (AXION-WIMP
                       2014) / Tsesmelis, Emmanuel, Maroudas,
                       Marios (eds.), Verlag Deutsches
                       Elektronen-Synchrotron : 2014 ;
                       AXION-WIMP 2014 : 10th Patras Workshop
                       on Axions, WIMPs and WISPs, 2014-06-29
                       - 2014-07-04, Geneva},
      abstract     = {An X-ray detector based on the combination of an integrated
                      Micromegas stage with apixel chip has been built in order to
                      be installed at the CERN Axion Solar Telescope.Due to its
                      high granularity and spatial resolution this detector allows
                      for a topologicalbackground suppression along with a
                      detection threshold below 1 keV.Tests at the CAST Detector
                      Lab show the detector’s ability to detect X-ray photons
                      downto an energy as low as 277 eV. The first background data
                      taken after the installation atthe CAST experiment underline
                      the detector’s performance with an average backgroundrate
                      of 5 × 10$^{−5}$ /keV/cm$^2$/s between 2 and 10 keV when
                      using a lead shielding.},
      month         = {Jun},
      date          = {2014-06-29},
      organization  = {10th Patras Workshop on Axions, WIMPs
                       and WISPs, Geneva (Switzerland), 29 Jun
                       2014 - 4 Jul 2014},
      typ          = {PUB:(DE-HGF)8 / PUB:(DE-HGF)7},
      doi          = {10.3204/DESY-PROC-2014-03/krieger_christoph},