MDE

Latest additions:
2018-08-17
16:07
[PUBDB-2018-03040] Book/Report
;
Ground Vibration Measurements at the Proposed ALBA Site in Barcelona
[TESLA Report 2005-10]
TESLA Reports 15 pp. ()
ALBA, a new generation synchrotron light source for Spain, is presently in the con-struction phase. The proposed site is located in Cerdanyola del Vallès, near Barcelona [...]
Restricted: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2018-06-26
10:18
OpenAccess [PUBDB-2018-02380] Contribution to a conference proceedings
; ; ; et al
Automatic Tuning of PETRA, its Injector Complex, and Prospects of Autonomous Operation of PETRA IV
9th International Particle Accelerator Conference, IPAC’18, VancouverVancouver, Canada, 29 Apr 2018 - 4 May 20182018-04-292018-05-04 4 pp. () [10.3204/PUBDB-2018-02380]  GO
We present the progress in tuning automation of the PETRAinjection complex. The OCELOT optimizer has beenported to the PETRA control system and proof-of-principletests of transmission efficiency optimization done. [...]
OpenAccess: wepaf044 - Download fulltextPDF Download fulltextPDF (PDFA); Agapov_WEPAF044 - Download fulltextPDF;

Detailed record - Similar records
2017-11-23
16:17
OpenAccess [PUBDB-2017-12256] Poster
; ; ; et al
Quadrupole Scan Measurements in the Beam Transport Line between DESY II and PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19  GO
PETRA III is a 6 GeV third generation synchrotron light source in Hamburg, Germany. The storage ring is operated with a typical beam current of 100 mA and is running in top-up mode. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-11-14
12:09
OpenAccess [PUBDB-2017-11955] Contribution to a conference proceedings/Contribution to a book
; ; ; et al
Linear and Nonlinear Optics Measurements With Multiturn Data at PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19 JACoW, Geneva, Switzerland 4 pp. () [10.18429/JACoW-IPAC2017-MOPAB040]  GO
At Petra III measuring multiturn beam response to pulsed and continuous excitations allows linear and nonlinear (e.g. frequency maps) optics parameter determination. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-08-28
14:48
OpenAccess [PUBDB-2017-09997] Contribution to a conference proceedings/Contribution to a book
; ; ; et al
PETRA III Operation
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19 Geneva : JACoW 2589-2591 () [10.18429/JACoW-IPAC2017-WEPAB014]  GO
At DESY the Synchrotron Light Source PETRA III offers scientists outstanding opportunities for experiments with hard X-rays of exceptionally high brilliance since 2009. This paper describes the challenges of daily operation, including different bunch patterns and their side effects, a procedure to clear spurious bunches, the operational statistics and the main contributions to down time..
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA); Restricted: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-08-28
14:00
OpenAccess [PUBDB-2017-09981] Poster
; ; ; et al
PETRA III Operation
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19  GO
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-07-04
14:52
OpenAccess [PUBDB-2017-06860] Contribution to a conference proceedings
; ; ; et al
Dispersion and Beam Optic Parameter Measurements in the Transport Line (E-Weg) from DESY II To PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19 692-694 () [10.3204/PUBDB-2017-06860]  GO
The transport line E-Weg extends from the extraction septum in DESY II to the injection septum in PETRA III, and transports electrons at a beam energy of 6.0 GeV. It consists of 3 parts. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-07-03
14:43
OpenAccess [PUBDB-2017-06695] Contribution to a conference proceedings
; ; ; et al
Quadrupole Scan Measurements in the Beam Transport Line between DESY II and PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19 174-176 () [10.3204/PUBDB-2017-06695]  GO
PETRA III is a 6 GeV third generation synchrotron light source in Hamburg, Germany. The storage ring is operated with a typical beam current of 100 mA and is running in top-up mode. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-05-31
19:19
OpenAccess [PUBDB-2017-04128] Poster
; ; ; et al
Dispersion and Beam Optic Parameter Measurements in the Transport Line (E-Weg) from DESY II To PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19  GO
The transport line E-Weg extends from the extraction septum in DESY II to the injection septum in PETRA III, and transports electrons at a beam energy of 6.0 GeV. It consists of 3 parts. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2016-12-20
13:57
OpenAccess [PUBDB-2016-06437] Contribution to a conference proceedings
; ; ; et al
Automated Availability Statistics
11th International Workshop on Personal Computers and Particle Accelerator Controls, PCaPAC 2016, CampinasCampinas, Brazil, 25 Oct 2016 - 28 Oct 20162016-10-252016-10-28 not yet defined () [10.3204/PUBDB-2016-06437]  GO
The availability of a particle accelerator or any large machine with users is not only of paramount importance but is also, at the end of the day, an oft quoted number (0 to 100%) which represents (or is taken to represent) the overall health of the facility in question. When a single number can somehow reflect on the maintenance, operation, and engineering of the machine, it is important to know how this number was obtained. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records