MDE

Latest additions:
2019-11-19
10:24
OpenAccess [PUBDB-2019-04296] Conference Presentation
et al
The Injection System and the Injector Complex for PETRA IV
10th International Particle Accelerator Conference, IPAC'19, MelbourneMelbourne, Australia, 19 May 2019 - 24 May 20192019-05-192019-05-24  GO
PETRA IV project is to upgrade PETRA III to a synchrotron radiation source with an ultra-low emittance. Due to the small dynamic aperture of the PETRA IV storage ring, a horizontal on-axis injection is prepared. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA); External link: Download fulltextFulltext

Detailed record - Similar records
2019-10-11
17:13
[PUBDB-2019-03662] Contribution to a conference proceedings
et al
Status of the PETRA IV project
10th International Particle Accelerator Conference, IPAC'19, MelbourneMelbourne, Australia, 19 May 2019 - 24 May 20192019-05-192019-05-24 JACoW Publishing, Geneva, Switzerland 1404-1407 () [10.18429/JACOW-IPAC2019-TUPGW011]  GO
Since 2016 DESY has been pursuing R towards upgrading its PETRA synchrotron light source to a fourth-generation machine, PETRA IV, which is expected to start operation in 2027. The conceptual design of a 6 GeV seven-bend-achromat-based lattice with an approx. [...]
Restricted: Download fulltextPDF Download fulltextPDF (PDFA); External link: Download fulltextFulltext

Detailed record - Similar records
2019-02-18
15:43
arXiv [PUBDB-2019-01144] Report/Journal Article
et al
The DESY II Test Beam Facility
[DESY-18-111; arXiv:1807.09328]
DESY Hamburg operates a test beam facility with three independent beam lines at the DESY II synchrotron. It is world-wide one of very few facilities providing test beams in the GeV range. [...]
External link: Download fulltextFulltext
ddc:530
Detailed record - Similar records
2019-02-18
09:52
Embargoed OpenAccess [PUBDB-2019-01134] Report/Journal Article
et al
The DESY II Test Beam Facility
[arXiv:1807.09328; DESY-18-111]
DESY Hamburg operates a test beam facility with three independent beam lines at the DESY II synchrotron. It is world-wide one of very few facilities providing test beams in the GeV range. [...]
Published on 2018-12-05. Available in OpenAccess from 2019-12-05.: Download fulltextPDF Download fulltextPDF (PDFA); Restricted: Download fulltextPDF Download fulltextPDF (PDFA);
ddc:530
Detailed record - Similar records
2018-08-17
16:07
[PUBDB-2018-03040] Book/Report

Ground Vibration Measurements at the Proposed ALBA Site in Barcelona
[TESLA Report 2005-10]
TESLA Reports 15 pp. ()
ALBA, a new generation synchrotron light source for Spain, is presently in the con-struction phase. The proposed site is located in Cerdanyola del Vall├Ęs, near Barcelona [...]
Restricted: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2018-08-07
10:53
OpenAccess [PUBDB-2018-02765] Preprint/Report
et al
The DESY II Test Beam Facility
[DESY-18-111; arXiv:1807.09328]
 GO
DESY Hamburg operates a test beam facility with three independent beam lines at the DESY II synchrotron. It is world-wide one of very few facilities providing test beams in the GeV range. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2018-06-26
10:18
OpenAccess [PUBDB-2018-02380] Contribution to a conference proceedings
et al
Automatic Tuning of PETRA, its Injector Complex, and Prospects of Autonomous Operation of PETRA IV
9th International Particle Accelerator Conference, IPAC'18, VancouverVancouver, Canada, 29 Apr 2018 - 4 May 20182018-04-292018-05-04 4 pp. () [10.3204/PUBDB-2018-02380]  GO
We present the progress in tuning automation of the PETRAinjection complex. The OCELOT optimizer has beenported to the PETRA control system and proof-of-principletests of transmission efficiency optimization done. [...]
OpenAccess: wepaf044 - Download fulltextPDF Download fulltextPDF (PDFA); Agapov_WEPAF044 - Download fulltextPDF;

Detailed record - Similar records
2017-11-23
16:17
OpenAccess [PUBDB-2017-12256] Poster
et al
Quadrupole Scan Measurements in the Beam Transport Line between DESY II and PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19  GO
PETRA III is a 6 GeV third generation synchrotron light source in Hamburg, Germany. The storage ring is operated with a typical beam current of 100 mA and is running in top-up mode. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-11-14
12:09
OpenAccess [PUBDB-2017-11955] Contribution to a conference proceedings/Contribution to a book
et al
Linear and Nonlinear Optics Measurements With Multiturn Data at PETRA III
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19 JACoW, Geneva, Switzerland 4 pp. () [10.18429/JACoW-IPAC2017-MOPAB040]  GO
At Petra III measuring multiturn beam response to pulsed and continuous excitations allows linear and nonlinear (e.g. frequency maps) optics parameter determination. [...]
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records
2017-08-28
14:48
OpenAccess [PUBDB-2017-09997] Contribution to a conference proceedings/Contribution to a book
et al
PETRA III Operation
8th International Particle Accelerator Conference, IPAC2017, CopenhagenCopenhagen, Denmark, 14 May 2017 - 19 May 20172017-05-142017-05-19 Geneva : JACoW 2589-2591 () [10.18429/JACoW-IPAC2017-WEPAB014]  GO
At DESY the Synchrotron Light Source PETRA III offers scientists outstanding opportunities for experiments with hard X-rays of exceptionally high brilliance since 2009. This paper describes the challenges of daily operation, including different bunch patterns and their side effects, a procedure to clear spurious bunches, the operational statistics and the main contributions to down time..
OpenAccess: Download fulltextPDF Download fulltextPDF (PDFA); Restricted: Download fulltextPDF Download fulltextPDF (PDFA);

Detailed record - Similar records